AndAny Engine Configuration Parameters

An AndAny ESP task compares two tracks and produces a track containing records from the first track for which there is at least one event in the second track within a specified time interval (before or after the first track's event). This section describes the parameters that you can set in the configuration section for an AndAny ESP task.

Configuration Parameter Description
Input0 The first input track. A record from this track is added to the output if a record occurs in the second track within the specified time interval. If the LuaScript parameter is set your Lua function must also return true, otherwise the record is discarded.
Input1 The second input track. Records from this track are never added to the output.
LuaScript The path of a Lua script that contains a function to determine whether a record should be included in the output track.
MaxTimeInterval The maximum interval from a record in the first track to a record in the second track, for the record in the first track to be included in the output.
MinTimeInterval The minimum interval from a record in the first track to a record in the second track, for the record in the first track to be included in the output.
Type The type of ESP engine to use. Set this parameter to AndAny.

Output Tracks

This engine produces a single output track, named TaskName.Output. The output track has the same format as the input track Input0.