AddTimingsToMetadata

A Boolean value that specifies whether to add the start time and duration for each detected word, sentence boundary, and period of silence to the document metadata.

If you set this parameter to TRUE, HPE CFS adds metadata fields named SpeechToTextWord with attributes describing the start time and duration:

<SpeechToTextWord start="3.1562" duration="0.3568">hello</SpeechToTextWord>
Type: Boolean
Default: False
Required No
Configuration Section: Any section that you have defined for IDOL Speech settings
Example: AddTimingsToMetadata=TRUE
See Also: AddConfidenceToMetadata